The SDT continuous-row system shows its strengths in the variety of products for standard applications. Having matured over many years of use, it has grown steadily in line with practical requirements. With these advantages, renovation solutions in particular are no challenge.
The diversity of the SDT system has the right answer for every task. With our quick-mounting system, rooms with the most diverse requirements can be illuminated economically. It is predestined for lighting solutions in the industrial, logistics, office, education and retail sectors. Because all gear trays have the tried and tested system length, refurbishments can also be easily realized. The various technologies can optimally bring their strengths and special possibilities to bear.✔ Optimal lighting conditions thanks to selectable device versions with top performance
✔ Replaceable
✔ Allow modernization
✔ Extend the service life of the entire system in a future-proof manner
Line | SDG(V)OXB | SDG(V)OB | SDG(V)OTB | SDG(V)OT | SDG(V)OH | SDG(V)OG | SDGODA | SDGOA | SDG(V)LB | SDG(V)LT | SDG(V)LK | SDGLDA | SDGV(L) | SDGBG |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data | ||||||||||||||
Lighting technology | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens | Linear lens | Linear lens | Diffuser | Linear lens | Diffuser | Diffuser |
Light distribution | direct, extremely wide distribution | direct wide distribution | direct narrow/wide distribution | direct, narrow distribution | direct, extremely narrow distribution | direct/indirect diffuse distribution | direct double asymmetrical distribution | direct asymmetrical distribution | direct wide distribution | direct, narrow distribution | direct/indirect distribution | direct double asymmetrical distribution | direct diffuse distribution. | direct/indirect diffuse distribution |
Light distribution curve | ||||||||||||||
Radiation angle | 105 ° (C0) / 105 ° (C90) | 95 ° (C0) / 95 ° (C90) | 75 ° (C0) / 75 ° (C90) | 40 ° (C0) / 85 ° (C90) | 30 ° (C0) / 30 ° (C90) | 115 ° (C0) / 110 ° (C90) | 70 ° (C0) / 90 ° (C90) | 20 ° | 100 ° (C0) / 110 ° (C90) | 60 ° (C0) / 120 ° (C90) | 130 ° (C0) / 105 ° (C90) | 80 ° (C0) / 120 ° (C90) | 115 ° (C0) / 105 ° (C90) | 110 ° (C0) / 125 ° (C90) |
Mark of conformity | ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I γ 65°<3000 cd/m² |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I γ 65°<3000 cd/m² |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I γ 65°<3000 cd/m² |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I γ 65°<3000 cd/m² |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
HACCP DIN10500/Food/IFS-application-related suitability/BRC HCL Protection class I |
ENEC Protection class I |
Protection class | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 40 |
20 |
Impact resistance IK | IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) IK03 (5°C to 25°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) IK03 (5°C to 25°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) IK03 (5°C to 25°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) |
IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) IK03 (5°C to 25°C) |
IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) |
IK03 (10°C to 25°C) IK03 (10°C to 35°C) IK03 (10°C to 40°C) IK03 (10°C to 45°C) |
IK03 (10°C to 25°C) IK03 (10°C to 35°C) IK03 (10°C to 40°C) IK03 (10°C to 45°C) |
IK03 (10°C to 25°C) IK03 (10°C to 30°C) IK03 (10°C to 35°C) IK03 (10°C to 40°C) |
IK03 (10°C to 25°C) IK03 (10°C to 40°C) IK03 (10°C to 45°C) |
IK03 (10°C to 25°C) IK03 (10°C to 40°C) IK03 (10°C to 45°C) IK08 (10°C to 25°C) IK08 (10°C to 40°C) IK08 (10°C to 45°C) |
IK03 (25°C to 35°C) |
Ambient temperature | 25 °C 35 °C 40 °C 45 °C |
25 °C 35 °C 40 °C 45 °C |
25 °C 35 °C 40 °C 45 °C |
25 °C 35 °C 40 °C 45 °C |
25 °C 35 °C |
25 °C 35 °C 40 °C 45 °C |
25 °C 40 °C 45 °C |
40 °C 45 °C |
25 °C 35 °C 40 °C 45 °C |
25 °C 35 °C 40 °C 45 °C |
25 °C 30 °C 35 °C 40 °C |
25 °C 40 °C 45 °C |
25 °C 40 °C 45 °C |
35 °C |
Mounting type | Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
Ceiling-mounted mounting rail installation Ceiling-mounted mounting rail installation on T-system Mounting rail system installation Pendulum mounting rail assembly on chain Pendulum mounting rail installation on steel cable |
LxWxH/DxH | 1531 x 55 x 37 | 1531 x 55 x 33 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 63 x 46 1531 x 77 x 64 |
1531 x 55 x 41 1531 x 63 x 41 1531 x 77 x 59 |
1531 x 63 x 54 | 1531 x 55 x 46 1531 x 63 x 46 |
1531 x 55 x 43 | 1531 x 55 x 42 |
Module length | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 |
Luminaire luminous flux max. (lm) | 4.408 lm – 11.615 lm | 4.389 lm – 11.639 lm | 4.386 lm – 11.639 lm | 4.412 lm – 11.675 lm | 8.155 lm – 11.555 lm | 4.105 lm – 11.004 lm | 4.427 lm – 6.127 lm | 4.358 lm – 6.026 lm | 5.209 lm – 17.337 lm | 5.220 lm – 17.372 lm | 4.873 lm – 10.226 lm | 5.172 lm – 7.470 lm | 4.357 lm – 8.089 lm | 6.706 lm – 9.184 lm |
Luminaire efficiencies max. (lm/W) | 147 lm/W – 175 lm/W | 146 lm/W – 176 lm/W | 146 lm/W – 176 lm/W | 147 lm/W – 176 lm/W | 145 lm/W – 174 lm/W | 137 lm/W – 166 lm/W | 164 lm/W – 172 lm/W | 161 lm/W – 170 lm/W | 171 lm/W – 191 lm/W | 171 lm/W – 191 lm/W | 160 lm/W – 179 lm/W | 179 lm/W – 190 lm/W | 101 lm/W – 173 lm/W | 156 lm/W – 168 lm/W |
Light color | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 927-965 |
840 |
LED life | 50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 30°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
50000h L80/B10 (Tq 35°C) |
Operating devices | DALI2 ED ED EL-B3 EDM |
DALI2 ED ED EL-B3 EDM |
DALI2 ED EDM |
DALI2 ED ED EL-B3 |
DALI2 ED |
DALI2 ED EDM |
DALI2 ED ED EL-B3 |
DALI2 ED |
DALI2 ED ED EL-B3 EDM |
DALI2 ED ED EL-B3 |
DALI2 ED ED EL-B3 EDM |
DALI2 ED ED EL-B3 |
DALI DT8 DALI2 ED ED EL-B3 EDM |
DALI2 EDM |
Features | Emergency lighting Food |
Emergency lighting Food |
Food | Emergency lighting Food |
Food | Food | Emergency lighting Food |
Food | Emergency lighting Food |
Emergency lighting Food |
Emergency lighting Food |
Emergency lighting Food |
Emergency lighting Food Human Centric Lighting (HCL) |
Line | SDGSOXB | SDGSOB | SDGSOTB | SDGSOT | SDGSOH | SDGSOG | SDGSODA | SDGSOA |
---|---|---|---|---|---|---|---|---|
Data | ||||||||
Lighting technology | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens | Individual lens |
Light distribution | direct, extremely wide distribution | direct wide distribution | direct narrow/wide distribution | direct, narrow distribution | direct, extremely narrow distribution | direct/indirect diffuse distribution | direct double asymmetrical distribution | direct asymmetrical distribution |
Light distribution curve | ||||||||
Radiation angle | 105 ° (C0) / 105 ° (C90) | 95 ° (C0) / 95 ° (C90) | 75 ° (C0) / 75 ° (C90) | 40 ° (C0) / 85 ° (C90) | 30 ° (C0) / 30 ° (C90) | 115 ° (C0) / 110 ° (C90) | 70 ° (C0) / 90 ° (C90) | 20 ° |
Mark of conformity | D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I γ 65°<3000 cd/m² |
D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I γ 65°<3000 cd/m² |
D ENEC HACCP DIN10500/Food/IFS-application-related suitability/BRC Protection class I |
Protection class | 64 | 64 | 64 | 64 | 64 | 64 | 64 | 64 |
Impact resistance IK | IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) IK03 (5°C to 25°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) IK03 (5°C to 25°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (5°C to 25°C) |
IK03 (-20°C to 25°C) IK03 (-20°C to 35°C) IK03 (-20°C to 40°C) |
IK03 (-20°C to 40°C) | IK03 (-20°C to 40°C) IK03 (-20°C to 45°C) |
Ambient temperature | 25 °C 35 °C 40 °C |
25 °C 35 °C 40 °C |
25 °C 35 °C 40 °C |
25 °C 35 °C 40 °C |
25 °C 35 °C |
25 °C 35 °C 40 °C |
40 °C | 40 °C 45 °C |
Mounting type | Mounting rail system installation | Mounting rail system installation | Mounting rail system installation | Mounting rail system installation | Mounting rail system installation | Mounting rail system installation | Mounting rail system installation | Mounting rail system installation |
LxWxH/DxH | 1531 x 55 x 37 | 1531 x 55 x 33 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 | 1531 x 55 x 37 |
Module length | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 |
Luminaire luminous flux max. (lm) | 6.100 lm – 11.615 lm | 6.074 lm – 11.639 lm | 6.070 lm – 11.639 lm | 6.106 lm – 11.675 lm | 8.155 lm – 11.555 lm | 5.682 lm – 11.004 lm | 6.127 lm | 4.358 lm – 6.026 lm |
Luminaire efficiencies max. (lm/W) | 147 lm/W – 175 lm/W | 146 lm/W – 176 lm/W | 146 lm/W – 176 lm/W | 147 lm/W – 176 lm/W | 145 lm/W – 174 lm/W | 137 lm/W – 166 lm/W | 164 lm/W | 161 lm/W – 170 lm/W |
Light color | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 |
LED life | 50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) |
50000h L80/B10 (Tq 25°C) 50000h L80/B10 (Tq 35°C) 50000h L80/B10 (Tq 40°C) |
50000h L80/B10 (Tq 40°C) | 50000h L80/B10 (Tq 40°C) 50000h L80/B10 (Tq 45°C) |
Operating devices | DALI2 ED ED EL-B3 |
DALI2 ED ED EL-B3 EDM |
DALI2 ED |
DALI2 ED |
DALI2 ED ED EL-B3 |
DALI2 ED |
DALI2 ED |
DALI2 ED |
Features | Emergency lighting Food |
Emergency lighting Food |
Food | Food | Emergency lighting Food |
Food | Food | Food |